Altronix AL400ULACMCB — 8 PTC Outputs Access Power Controller / Power Supply (12/24 VDC @ 4A) | Vidimost Chicago
Model / Series: AL400ULACMCB
The Altronix AL400ULACMCB is an 8-output access power controller with built-in power supply / charger — converts 115 VAC into eight independently-controlled 12 / 24 VDC fail-safe / fail-secure outputs (4A @ 12 VDC or 3A @ 24 VDC total). Class 2 PTC-protected auto-resettable outputs (rated 2.5A each), Fire Alarm disconnect (latching / non-latching) per output, supports up to two 18 Ah / 12 VDC backup batteries. The Chicago choice for multi-door access control power with built-in fire-alarm interlock.
Specifications
- Brand
- Altronix
- Series
- Altronix ACMCB
- Model
- AL400ULACMCB
- Form Factor
- Indoor wall-mount access power controller with built-in power supply / charger
- Input
- 115 VAC, 60 Hz
- Output Configuration
- 8 independently-controlled outputs
- Output Voltage
- 12 VDC or 24 VDC (selectable)
- Total Output Current
- 4 A @ 12 VDC or 3 A @ 24 VDC
- Output Mode
- Fail-Safe and / or Fail-Secure (per output)
- Output Protection
- Class 2 PTC, auto-resettable; PTCs rated 2.5 A
- Fire Alarm Disconnect
- Latching or non-latching, individually selectable for any or all 8 outputs
- Battery Backup
- Supports up to two 18 Ah / 12 VDC sealed lead-acid batteries
- Other Protection
- Filtered + electronically regulated outputs; short-circuit and thermal overload protection
- Compatible Devices
- Magnetic locks, electric strikes, magnetic door holders
Best Fit & Recommended For
Altronix AL400ULACMCB Access Power Controller
The Altronix AL400ULACMCB is a multi-output access power controller with a built-in power supply / charger — converts a single 115 VAC input into eight independently-controlled 12 / 24 VDC fail-safe / fail-secure outputs, perfect for Chicago commercial properties powering 4–8 doors from a single panel. Each output is PTC-protected (auto-resettable, 2.5 A) and has individually-selectable Fire Alarm disconnect (latching or non-latching) — satisfying NFPA 101 / IBC interlock requirements for maglock and electric-strike installations.
What’s Confirmed by the Official Altronix Spec
These specifications come directly from Altronix’s published AL400ULACMCB product page:
- Input: 115 VAC, 60 Hz
- Outputs: 8 independently-controlled fail-safe / fail-secure outputs
- Output voltage: 12 VDC or 24 VDC selectable
- Total output current: 4 A @ 12 VDC or 3 A @ 24 VDC
- Output protection: Class 2 PTC, auto-resettable, rated 2.5 A per output
- Fire alarm disconnect: latching or non-latching, individually selectable per output
- Battery backup: supports up to two 18 Ah / 12 VDC sealed lead-acid batteries
- Built-in features: filtered + electronically regulated outputs; short-circuit and thermal overload protection
- Compatible devices: magnetic locks, electric strikes, magnetic door holders
When AL400ULACMCB Fits — Multi-Door Access Control Power
The AL400ULACMCB earns its place when the project requires:
- Multiple doors (typically 4–8) powered from a single centralized panel
- Fire-alarm interlock wired into the power circuit so the doors release on fire alarm (code requirement for maglocks per NFPA 101)
- Auto-resettable PTC protection so a temporary short on one door doesn’t blow a fuse and doesn’t require a service call to replace
- Battery backup with extended runtime (two 18 Ah / 12 VDC batteries)
AL400ULACMCB vs. Other Altronix Multi-Output
| Model | Outputs | Total Current | Protection |
|---|---|---|---|
| AL400ULACMCB (this page) | 8 outputs | 4 A @ 12 VDC / 3 A @ 24 VDC | PTC auto-resettable |
| AL600ULACM | 8 outputs | 6 A @ 12 / 24 VDC | Fused (3.5 A per output, 10 A main) |
| AL600ULMX | 5 outputs | 6 A @ 12 / 24 VDC | Individually protected per output |
| AL400ULX | 1 output | 4 A @ 12 VDC / 3 A @ 24 VDC | Single Class 2 output |
For projects that need higher total current (6 A) and prefer fused-relay outputs, step up to the AL600ULACM. For single-output single-door applications, the AL400ULX is more economical.
Where the AL400ULACMCB Wins in Chicago
- Multi-door commercial access control with up to 8 doors per power controller
- Healthcare facility multi-door installations with fire-alarm interlock
- Education facility classroom-cluster access control
- Multi-tenant residential building common-area door clusters
- Office building floor-by-floor access deployments
- Hospitality back-of-house multi-door power
- Retail back-of-house multi-door power
- Industrial / warehouse personnel-door multi-output power
- Government / municipal multi-door installations with fire-alarm interlock
- Property management portfolio standardized multi-door power
Local Chicago Coverage
Vidimost installs the Altronix AL400ULACMCB across the full Chicago metropolitan area for multi-door access control power with fire-alarm interlock.
Recommended Pairings
- Altronix AL600ULACM — higher-current 6 A sibling with fused-relay outputs
- Altronix AL600ULMX — 5-output 6 A multi-output power
- Altronix AL400ULX — single-output sibling for one-door applications
- Sealed lead-acid backup batteries — up to two 18 Ah / 12 VDC batteries
Professional Installation by Vidimost
Vidimost LLC installs the Altronix AL400ULACMCB across Chicago for multi-door access control deployments. Full-scope service includes site walkthrough, output assignment per door, fire-alarm interlock wiring (per NFPA 101 / IBC), battery sizing for runtime requirement, AC primary wiring, integration with the access control panel and door hardware, and operator training. Contact us for a free site walkthrough and quote.
Frequently Installed Together
Altronix
Altronix AL600ULACM
The Altronix AL600ULACM is an 8-output access power controller with built-in 6 A power supply / charger — converts 115 VAC into eight independently-controlled 12 / 24 VDC fail-safe / fail-secure outputs (6 A total). Fused-relay outputs (3.5 A per output, 10 A main fuse), Fire Alarm disconnect (latching / non-latching) per output, AC fail supervision, built-in battery charger (0.7 A max). The Chicago choice for higher-current multi-door access control with code-compliant fire-alarm interlock.
View →Altronix
Altronix AL600ULMX
The Altronix AL600ULMX is a 5-output Class 2 multi-output power supply / charger — 115 VAC input, 12 / 24 VDC selectable, 6 A total continuous current, individually-protected outputs. Lighter-duty companion to the ACM access power controllers when the project just needs distributed clean power without per-output fail-safe / fail-secure switching. The Chicago choice for CCTV multi-camera deployments and access control sites where the panel handles fail-mode switching and the AL600ULMX just delivers stable distributed power.
View →Altronix
Altronix AL400ULX
The Altronix AL400ULX is a single-output power supply / charger for access control, burglar alarm, and fire signaling applications — converts 115 VAC / 60 Hz into a Class 2 power-limited output of either 12 VDC @ 4A or 24 VDC @ 3A. Built-in charger for sealed lead-acid / gel batteries, automatic switchover on AC loss, 13"×13.5"×3.25" wall-mount enclosure. UL294 / UL603 / UL1481 / UL1069 listed.
View →