Model / Series: AL400ULACMCB

The Altronix AL400ULACMCB is an 8-output access power controller with built-in power supply / charger — converts 115 VAC into eight independently-controlled 12 / 24 VDC fail-safe / fail-secure outputs (4A @ 12 VDC or 3A @ 24 VDC total). Class 2 PTC-protected auto-resettable outputs (rated 2.5A each), Fire Alarm disconnect (latching / non-latching) per output, supports up to two 18 Ah / 12 VDC backup batteries. The Chicago choice for multi-door access control power with built-in fire-alarm interlock.

We don't just ship boxes — this goes in as part of our access control installation in Chicago work. City building? See our Chicago, IL service area.

Altronix AL400ULACMCB

Specifications

Brand
Altronix
Series
Altronix ACMCB
Model
AL400ULACMCB
Form Factor
Indoor wall-mount access power controller with built-in power supply / charger
Input
115 VAC, 60 Hz
Output Configuration
8 independently-controlled outputs
Output Voltage
12 VDC or 24 VDC (selectable)
Total Output Current
4 A @ 12 VDC or 3 A @ 24 VDC
Output Mode
Fail-Safe and / or Fail-Secure (per output)
Output Protection
Class 2 PTC, auto-resettable; PTCs rated 2.5 A
Fire Alarm Disconnect
Latching or non-latching, individually selectable for any or all 8 outputs
Battery Backup
Supports up to two 18 Ah / 12 VDC sealed lead-acid batteries
Other Protection
Filtered + electronically regulated outputs; short-circuit and thermal overload protection
Compatible Devices
Magnetic locks, electric strikes, magnetic door holders

Best Fit & Recommended For

Chicago multi-door commercial access control with up to 8 doors per power controller
Healthcare facility multi-door installations with fire-alarm interlock
Education facility classroom-cluster access control
Multi-tenant residential building common-area door clusters
Office building floor-by-floor access deployments
Hospitality back-of-house multi-door power
Retail back-of-house multi-door power
Industrial / warehouse personnel-door multi-output power
Government / municipal multi-door installations with fire-alarm interlock
Property management portfolio standardized multi-door power

Altronix AL400ULACMCB Access Power Controller

The Altronix AL400ULACMCB is a multi-output access power controller with a built-in power supply / charger — converts a single 115 VAC input into eight independently-controlled 12 / 24 VDC fail-safe / fail-secure outputs, perfect for Chicago commercial properties powering 4–8 doors from a single panel. Each output is PTC-protected (auto-resettable, 2.5 A) and has individually-selectable Fire Alarm disconnect (latching or non-latching) — satisfying NFPA 101 / IBC interlock requirements for maglock and electric-strike installations.

What’s Confirmed by the Official Altronix Spec

These specifications come directly from Altronix’s published AL400ULACMCB product page:

  • Input: 115 VAC, 60 Hz
  • Outputs: 8 independently-controlled fail-safe / fail-secure outputs
  • Output voltage: 12 VDC or 24 VDC selectable
  • Total output current: 4 A @ 12 VDC or 3 A @ 24 VDC
  • Output protection: Class 2 PTC, auto-resettable, rated 2.5 A per output
  • Fire alarm disconnect: latching or non-latching, individually selectable per output
  • Battery backup: supports up to two 18 Ah / 12 VDC sealed lead-acid batteries
  • Built-in features: filtered + electronically regulated outputs; short-circuit and thermal overload protection
  • Compatible devices: magnetic locks, electric strikes, magnetic door holders

When AL400ULACMCB Fits — Multi-Door Access Control Power

The AL400ULACMCB earns its place when the project requires:

  • Multiple doors (typically 4–8) powered from a single centralized panel
  • Fire-alarm interlock wired into the power circuit so the doors release on fire alarm (code requirement for maglocks per NFPA 101)
  • Auto-resettable PTC protection so a temporary short on one door doesn’t blow a fuse and doesn’t require a service call to replace
  • Battery backup with extended runtime (two 18 Ah / 12 VDC batteries)

AL400ULACMCB vs. Other Altronix Multi-Output

ModelOutputsTotal CurrentProtection
AL400ULACMCB (this page)8 outputs4 A @ 12 VDC / 3 A @ 24 VDCPTC auto-resettable
AL600ULACM8 outputs6 A @ 12 / 24 VDCFused (3.5 A per output, 10 A main)
AL600ULMX5 outputs6 A @ 12 / 24 VDCIndividually protected per output
AL400ULX1 output4 A @ 12 VDC / 3 A @ 24 VDCSingle Class 2 output

For projects that need higher total current (6 A) and prefer fused-relay outputs, step up to the AL600ULACM. For single-output single-door applications, the AL400ULX is more economical.

Where the AL400ULACMCB Wins in Chicago

  • Multi-door commercial access control with up to 8 doors per power controller
  • Healthcare facility multi-door installations with fire-alarm interlock
  • Education facility classroom-cluster access control
  • Multi-tenant residential building common-area door clusters
  • Office building floor-by-floor access deployments
  • Hospitality back-of-house multi-door power
  • Retail back-of-house multi-door power
  • Industrial / warehouse personnel-door multi-output power
  • Government / municipal multi-door installations with fire-alarm interlock
  • Property management portfolio standardized multi-door power

Local Chicago Coverage

Vidimost installs the Altronix AL400ULACMCB across the full city of Chicago for multi-door access control power with fire-alarm interlock.

  • Altronix AL600ULACM — higher-current 6 A sibling with fused-relay outputs
  • Altronix AL600ULMX — 5-output 6 A multi-output power
  • Altronix AL400ULX — single-output sibling for one-door applications
  • Sealed lead-acid backup batteries — up to two 18 Ah / 12 VDC batteries

Professional Installation by Vidimost

Vidimost LLC installs the Altronix AL400ULACMCB across Chicago for multi-door access control deployments. Full-scope service includes site walkthrough, output assignment per door, fire-alarm interlock wiring (per NFPA 101 / IBC), battery sizing for runtime requirement, AC primary wiring, integration with the access control panel and door hardware, and operator training. Contact us for a free site walkthrough and quote.

Frequently Installed Together

Altronix

Altronix AL600ULACM

The Altronix AL600ULACM is an 8-output access power controller with built-in 6 A power supply / charger — converts 115 VAC into eight independently-controlled 12 / 24 VDC fail-safe / fail-secure outputs (6 A total). Fused-relay outputs (3.5 A per output, 10 A main fuse), Fire Alarm disconnect (latching / non-latching) per output, AC fail supervision, built-in battery charger (0.7 A max). The Chicago choice for higher-current multi-door access control with code-compliant fire-alarm interlock.

View →

Altronix

Altronix AL600ULMX

The Altronix AL600ULMX is a 5-output Class 2 multi-output power supply / charger — 115 VAC input, 12 / 24 VDC selectable, 6 A total continuous current, individually-protected outputs. Lighter-duty companion to the ACM access power controllers when the project just needs distributed clean power without per-output fail-safe / fail-secure switching. The Chicago choice for CCTV multi-camera deployments and access control sites where the panel handles fail-mode switching and the AL600ULMX just delivers stable distributed power.

View →

Altronix

Altronix AL400ULX

The Altronix AL400ULX is a single-output power supply / charger for access control, burglar alarm, and fire signaling applications — converts 115 VAC / 60 Hz into a Class 2 power-limited output of either 12 VDC @ 4A or 24 VDC @ 3A. Built-in charger for sealed lead-acid / gel batteries, automatic switchover on AC loss, 13"×13.5"×3.25" wall-mount enclosure. UL294 / UL603 / UL1481 / UL1069 listed.

View →