Skip to content
Vidimost
Security Systems & Networking

HES 9500 Genesis III Surface-Mounted Fire-Rated Electric Strike — 3-hr UL 10C for Chicago Commercial

Model / Series: 9500

The HES 9500 Series is a 3-hour fire-rated, surface-mounted electric strike for commercial rim exit devices with a 3/4" Pullman latch. Components fully encased within a 3/4"-thick stainless steel housing — no frame cutting required. 1,500 lbs static / 70 ft-lbs dynamic, exceeds Grade 1, field-selectable fail-secure / fail-safe and 12 / 24 VDC, UL 10C fire-rated, UL 1034 burglary-resistant, NFPA 80-07 compliant for retrofit into fire-rated frames. The Chicago choice for fire-rated rim-exit retrofits.

HES 9500

Specifications

Brand
HES (an ASSA ABLOY brand)
Series
HES 9500 Genesis III
Model
9500
Form Factor
Surface-mounted fire-rated electric strike for rim exit devices
Fire Rating
3-hour UL 10C (fail-secure only); NFPA 80-07 compliant for retrofit into fire-rated frames
Profile
3/4 in thick — components fully encased within stainless steel housing; no frame cutting required
Latchbolt Accommodation
Rim exit devices with 3/4 in Pullman latch
Static Strength
1,500 lbs (per HES spec)
Dynamic Strength
70 ft-lbs (per HES spec); exceeds Grade 1 standards
Voltage
Field-selectable 12 / 24 VDC
Operation Mode
Field-selectable fail-secure / fail-safe
Compliance
ANSI Grade 1 exceeded; UL 10C fire-rated (3 hr, fail-secure); UL 1034 burglary-resistant; NFPA 80-07

Best Fit & Recommended For

Chicago commercial fire-rated rim-exit retrofits
Education facility fire-rated exit doors (corridors, stairwells)
Healthcare facility fire-rated rim-exit egress doors
Multi-tenant residential fire-rated stairwell and corridor exit doors
Office building fire-rated stairwell exit doors
Government / municipal fire-rated exit doors
Hospitality fire-rated back-of-house exits
Retail fire-rated rear-exit doors
Industrial / warehouse fire-rated personnel exits
NFPA 80-07 compliant retrofits into existing fire-rated frames

HES 9500 Genesis III Fire-Rated Surface-Mounted Electric Strike

The HES 9500 Series Genesis III is the fire-rated sibling of the HES 9400 — a 3-hour UL 10C fire-rated surface-mounted electric strike for commercial rim exit devices with a 3/4” Pullman latch. All components are completely encased within the 3/4”-thick stainless steel housing, so installation requires no cutting on the frame, making it ideal for retrofitting fire-rated openings (NFPA 80-07 compliant for retrofit into fire-rated frames). Field-selectable 12 / 24 VDC and field-selectable fail-secure / fail-safe operation.

What’s Confirmed by the Official HES Spec

These specifications come from HES product documentation:

  • Fire rating: 3-hour UL 10C (fail-secure only)
  • Profile: 3/4 in thick — components fully encased; no frame cutting required
  • Latchbolt accommodation: rim exit devices with 3/4 in Pullman latch
  • Static strength: 1,500 lbs
  • Dynamic strength: 70 ft-lbs
  • Voltage: field-selectable 12 / 24 VDC
  • Operation mode: field-selectable fail-secure / fail-safe (note: fire-rated 3-hr applies to fail-secure only)
  • Compliance: ANSI Grade 1 exceeded; UL 10C fire-rated; UL 1034 burglary-resistant; NFPA 80-07 compliant retrofit

9500 vs. 9400 — When Each Fits

Feature9500 (this page)HES 9400
Profile3/4 in thick5/8 in thick (slimmer)
Latchbolt accommodation3/4 in Pullman latchUp to 1/2 in throw
Fire rating3-hr UL 10C (fail-secure)NOT fire-rated
NFPA 80-07Yes, retrofit-compliantNo
Best fitFire-rated rim exit doorsNon-fire-rated rim exit doors

For any fire-rated opening, use the 9500. For non-fire-rated openings where the slimmer 5/8” profile is preferred, use the 9400.

Where the HES 9500 Wins in Chicago

  • Commercial fire-rated rim-exit retrofits
  • Education facility fire-rated exit doors (corridors, stairwells)
  • Healthcare facility fire-rated rim-exit egress doors
  • Multi-tenant residential fire-rated stairwell and corridor exit doors
  • Office building fire-rated stairwell exit doors
  • Government / municipal fire-rated exit doors
  • Hospitality fire-rated back-of-house exits
  • Retail fire-rated rear-exit doors
  • Industrial / warehouse fire-rated personnel exits
  • NFPA 80-07 compliant retrofits into existing fire-rated frames

Local Chicago Coverage

Vidimost installs the HES 9500 Series across the full Chicago metropolitan area for fire-rated rim-exit retrofits.

  • HES 9400 — non-fire-rated sibling for non-fire-rated openings on the same project
  • HES 4500C — internally-mounted fire-rated alternative for cylindrical / mortise openings
  • HES 1006 — heavy-duty internally-mounted Grade 1 strike (fire-rated SKUs available)

Professional Installation by Vidimost

Vidimost LLC installs the HES 9500 Series across Chicago for fire-rated rim-exit retrofits. Full-scope service includes site walkthrough, fire-rating verification of the opening and frame, surface-mount installation per NFPA 80-07 compliance procedure, field selection of voltage and fail-mode (fire-rated requires fail-secure), and integration with the access control panel and existing exit device. Contact us for a free site walkthrough and quote.

Frequently Installed Together